VOLTAGE STANDING WAVE RATIO (VSWR) METERES
It is a high gain, voltage, amplifier tuned at the centre frequency of 1khz. it is used for measuring VSWR , attenuation and total mismatch on the line .
SPECIFICATION OF VSWR, MODEL SW-115
Sensitivity |
0.2μV at a 200 ohms input for full scale deflection |
Noise Level |
At least 5 dB below full scale at rated sensitivity and maximum band width input terminated in 100 ohms and 500 ohms for crystal low and high respectively . |
Calibration |
Square law, meter indicates SWR, dB |
Range |
70 dB, input attenuator provides 60 dB in 10 dB steps, accuracy + 0.2 dB per 10 dB steps Maximum commutative error + 0.5 dB |
Scale selector |
Normal Expand and – 5dB |
Meter Scale |
SWR1-4,SWR 3-10 , expand SWR 1.1.3, dB 0-10, expand dB0.2 |
Gain Control |
Adjust the reference level, variable range 0-10 dB approx. |
Input |
“Bolo†bias provided for 4.3 mA low current bolo meters |
Recorder output |
Socket provided for recording having 1 V for full scale deflection, internal resistance of 1000 ohms or less |
A/C Output |
BNC connector for amplified output |
Input connector |
BNC (F) |
Frequency |
1000Hz + 10% |
Power |
230 volts A.C + 50 Hz, mains supply |